Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Rev. bras. ortop ; 57(5): 734-740, Sept.-Oct. 2022. tab, graf
Article in English | LILACS | ID: biblio-1407689

ABSTRACT

Abstract Objective The management of bone loss represents a challenge in revisions of total knee arthroplasty (rTKA) and in complex primary total knee arthroplasties (TKAs). The purpose of the present study was to evaluate the midterm outcomes (5-year minimum follow-up) of knee reconstructions with tantalum trabecular metal (TM) cones on bone defects Anderson Orthopaedics Research Institute (AORI) 2 and 3. Materials and MethodsA retrospective analysis of the medical records of patients operated on between July 2008 and November 2014 was performed, collecting the following data: age, gender, laterality, body mass index, etiology of arthrosis, comorbidities, AORI classification of bone defects, causes for revision, readmissions, reoperations, perioperative and postoperative complications, radiographic signs of osteointegration, and maintenance of the TM support. Results A total of 11 patients with a mean follow-up of 7.28 years (standard deviation [SD] = 1.88; range = 5.12-10 years) was evaluated, with 1 patient operated upon for a primary arthroplasty, 6 for revision arthroplasties, and 4 for a second revision arthroplasty (re-revision). There were complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component in three of the patients that led to the necessity of four procedures due to complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component. Radiological signs of osteointegration of the trabecular cones were observed in all patients. We did not observe migration of the TM cones or the prosthetic components in the sample. Conclusion The tantalum metaphyseal cones were able to provide efficient structural support to prosthetic implants with radiographic signs of osteointegration in the medium term.


Resumo Objetivo O manejo da perda óssea representa um grande desafio em cirurgias de revisão de artroplastia do joelho (rATJ) e em artroplastias totais do joelho (ATJ) primárias complexas. O objetivo do presente estudo foi avaliar os resultados em médio prazo (seguimento mínimo de 5 anos) das reconstruções de joelho nas quais cones de metal trabecular (MT) de tântalo foram utilizados para tratamento de defeitos ósseos tipos 2 e 3, de acordo com a classificação proposta pela Anderson Orthopaedic Research Institute (AORI). Métodos Feita análise retrospectiva dos prontuários dos pacientes operados entre julho de 2008 e novembro de 2014, coletando-se os seguintes dados: idade, gênero, lateralidade, índice de massa corporal, etiologia da artrose, comorbidade, classificação AORI da falha óssea, causa da revisão da artroplastia total do joelho, reinternações, reoperações, complicações peri- e pós-operatórias, ocorrência de osteointegração radiográfica e manutenção da função de suporte do MT. Resultados Foram avaliados 11 pacientes com tempo médio de seguimento de 7,28 anos (desvio padrão [DP] = 1,88; variação = 5,12-10 anos), sendo que 1 paciente foi submetido a artroplastia primária, 6 a artroplastia de revisão e 4 a segunda revisão de artroplastia (re-revisão). Três pacientes necessitaram de quatro reoperações devido a complicações com a ferida operatória, a lesão do mecanismo extensor e a soltura do componente femoral. Sinais de osteointegração dos cones trabeculados foram observados em todos os pacientes. Não observamos migração do cone de MT ou dos componentes protéticos. Conclusão Os cones metafisários de tântalo foram capazes de prover suporte estrutural eficiente aos implantes protéticos com sinais radiográficos de osteointegração em médio prazo.


Subject(s)
Humans , Postoperative Complications , Tantalum , Retrospective Studies , Osseointegration , Outcome Assessment, Health Care , Arthroplasty, Replacement, Knee , Knee Prosthesis
2.
Rev. bras. ortop ; 51(3): 282-289, tab, graf
Article in English | LILACS | ID: lil-787726

ABSTRACT

To define the anthropometric profile of the knee in a Brazilian population with gonarthrosis using intraoperative measurements; and to evaluate the compatibility of three implants available for total knee arthroplasty. METHODS: Morphometric data were collected prospectively from 117 subjects with gonarthrosis. Six dimensions in the distal femur and two in the proximal tibia were documented in 118 knees while performing total arthroplasty. These data were compared with the dimensions of three implants available for total knee arthroplasty. RESULTS: The statistical analysis showed that more than a quarter of the patients presented an unsatisfactory relationship between the knee and prosthesis. CONCLUSION: The implants evaluated need to be adjusted to better fit Brazilian patients.


Definir o perfil antropométrico do joelho em população brasileira portadora de gonartrose, com o uso da mensuração intraoperatória, e avaliar a compatibilidade de três implantes disponíveis para artroplastia total do joelho. MÉTODOS: Foram coletados, de forma prospectiva, os dados morfométricos de 117 pacientes portadores de gonartrose. Documentaram-se seis dimensões no fêmur distal e duas na tíbia proximal em 118 joelhos, durante a artroplastia total. Esses dados foram comparados com as dimensões dos três implantes disponíveis para artroplastia total do joelho. RESULTADOS: A análise estatística revelou que mais de um quarto dos pacientes apresentou relação inadequada entre os joelhos e as próteses. CONCLUSÃO: Os implantes avaliados necessitam de ajustes para melhor atender aos pacientes brasileiros.


Subject(s)
Humans , Male , Female , Anthropometry , Arthroplasty, Replacement, Knee , Femur
3.
Rev. bras. ortop ; 50(6): 743-746, Nov.-Dec. 2015. graf
Article in Portuguese | LILACS | ID: lil-769982

ABSTRACT

Avulsion fractures of the posterior cruciate ligament in unusual locations are rare injuries. We report the first case in the literature of an avulsion fracture of the posterior cruciate ligament associated with distal injury to the patellar ligament. The aim of this study was to present a novel case, the therapy used and the clinical follow-up.


A fratura avulsão do ligamento cruzado posterior em localização não usual é uma lesão rara. Relatamos o primeiro caso da literatura de uma fratura avulsão do ligamento cruzado posterior associada a lesão distal do ligamento patelar. O objetivo deste estudo foi apresentar um caso inédito, a terapêutica adotada e o seguimento clínico.


Subject(s)
Humans , Male , Adolescent , Fractures, Bone , Knee Injuries , Posterior Cruciate Ligament
4.
Rev. bras. ortop ; 50(4): 422-429, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-761119

ABSTRACT

Analisar e descrever, com o joelho em extensão, a distância da artéria poplítea em três áreas específicas da região proximal da tíbia, por meio de ressonância magnética. MÉTODOS: Foram analisadas as imagens de 100 joelhos de pacientes submetidos a exame por ressonância magnética. A localização da artéria poplítea foi medida em três áreas distintas da região proximal posterior da tíbia. A primeira medida foi feita no nível da articulação do joelho (platô tibial). A segunda, a 9 mm distal do platô tibial. A terceira, ao nível da tuberosidade anterior da tíbia (TAT). RESULTADOS: As distâncias entre a artéria poplítea e o platô tibial e a região da TAT foram significativamente maiores no sexo masculino do que no feminino. As distâncias entre a artéria poplítea e a região 9 mm distal do platô tibial e a TAT foram significativamente maiores na faixa acima de 36 anos do que na faixa ≤ 36 anos. CONCLUSÃO: O conhecimento da posição anatômica da artéria poplítea, demonstrada por estudos de RM, é de grande relevância no planejamento de procedimentos cirúrgicos que envolvam a articulação do joelho. Com isso, podem-se evitar lesões iatrogênicas devastadoras, principalmente em regiões proximais ao platô tibial e em pacientes jovens.


To analyze and describe the distance from the popliteal artery to three specific areas of the proximal region of the tibia, with the knee extended, by means of magnetic resonance. METHODS: Images of 100 knees of patients who underwent magnetic resonance examinations were analyzed. The location of the popliteal artery was measured in three different areas of the posterior proximal region of the tibia. The first measurement was made at the level of the knee joint (tibial plateau). The second was 9 mm distally to the tibial plateau. The third was at the level of the anterior tuberosity of the tibia (ATT). RESULTS: The distances between the popliteal artery and the tibial plateau and ATT region were significantly greater in males than in females. The distances between the popliteal artery and the regions 9 mm distally to the tibial plateau and the ATT were significantly greater in the age group over 36 years than in the group ≤36 years. CONCLUSION: Knowledge of the anatomical position of the popliteal artery, as demonstrated through magnetic resonance studies, is of great relevance in planning surgical procedures that involve the knee joint. In this manner, devastating iatrogenic injuries can be avoided, particularly in regions that are proximal to the tibial plateau and in young patients.


Subject(s)
Humans , Male , Female , Popliteal Artery/anatomy & histology , Knee , Magnetic Resonance Spectroscopy
5.
Rev. bras. ortop ; 48(5): 406-411, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697315

ABSTRACT

OBJECTIVE: Identify the etiology and incidence, as well to assess functional outcomes of patients, undergoing lower limb amputation after failure or complication of total knee arthroplasty. These patients were treated at the Center for Knee Surgery at the National Institute of Traumatology and Orthopedics (INTO), during the period of January 2001 to December 2010. METHODS: The patients were interviewed and their charts were retrospectively analyzed to evaluate their functional outcome. RESULTS: The incidence of amputation due to failure or complication of total knee arthroplasty was 0.41% in 2409 cases. Recurrent deep infection was the cause of amputation in 81% of cases, being Staphylococcus aureus and Pseudomonas aeruginosa the most frequent germs. Vascular complications and periprosthetic fracture associated to metaphyseal bone loss were also causes of amputation. In our study, 44% of amputees patients were using orthesis and 62.5% have had the ability to walk. CONCLUSION: Incidence of 0.41%, being the main cause recurrent infection. The functional outcome is limited, and the fitting achieved in 44% of patients and only 62.5% are ambulatory. .


OBJETIVO: Identificar a etiologia e a incidência da amputação do membro inferior após falha ou complicação da artroplastia total de joelho e avaliar os resultados funcionais dos pacientes tratados pelo Centro de Cirurgia de Joelho do Instituto Nacional de Traumatologia e Ortopedia (Into) entre janeiro de 2001 e dezembro de 2010. MÉTODOS: Os prontuários foram retrospectivamente analisados para coleta dos dados e entrevista para avaliação do resultado funcional. RESULTADOS: A incidência de amputação em decorrência de falha ou complicação após 2.409 artroplastias totais de joelho foi de 0,41%. Infecção profunda recorrente foi causa de amputação em 81% dos casos. Os germes mais frequentes foram Staphylococcus aureus e Pseu-domonas aeruginosa. Complicações vasculares e fratura periprotética associada a perda óssea metafisária representaram indicação em menor número de casos. Em nosso estudo, 44% dos pacientes amputados apresentam-se protetizados e 62,5% apresentavam capacidade de deambulação. CONCLUSÕES: Incidência de 0,41% e principal causa infecção recorrente. O resultado funcional é limitado, a protetização foi alcançada em 44% dos pacientes e somente 62,5% são deambuladores. .


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Amputation, Surgical , Arthroplasty, Replacement, Knee , Postoperative Complications
6.
Rev. bras. ortop ; 48(3): 257-262, May/June/2013. tab
Article in English | LILACS | ID: lil-680870

ABSTRACT

OBJECTIVE: to compare the laboratorial results of opening suction drainage 6 hours and 12 hours after total knee arthroplasty surgery. METHODS: prospective and randomized study in 88 patients undergoing with total knee arthroplasty in two groups: in one group the opening suction drainage was performed 6 hours (n = 45) after the surgery and in the other 12 hours (n = 43) after the surgery. RESULTS : the outcome was a significant fall in the three laboratorial variables (hemoglobin, red blood cells and hematocrit) between the pre and post-operative in the total sample and in the six and 12 hour opening suction drainage groups. In the group with opening suction drainage after 12 hours, the drainage volume was significantly lower than in the group with opening suction drainage after 6 hours (p = 0.0003). However, no significant difference was observed in the absolute delta of the laboratorial variables between the two groups. CONCLUSION: the opening suction drainage in six and 12 hours did not show significant difference from the laboratorial values although the volume of the blood drained was higher in the opening suction drainage in six hours. .


OBJETIVO: Comparar os resultados laboratoriais da abertura do dreno seis e 12 horas após a cirurgia de artroplastia total do joelho. MÉTODOS : Estudo prospectivo e randomizado em 88 pacientes tratados com artroplastia total do joelho com implante em dois grupos: um com abertura do dreno seis horas (n = 45) após a cirurgia e outro, 12 horas (n = 43) após a cirurgia. RESULTADOS : Existe uma queda significativa nas três variáveis laboratoriais (hemoglobina, hemácias e hematócrito) entre o pré e o pósoperatório na amostra total e nos grupos de tempo de abertura do dreno às seis e 12 horas. O grupo com tempo de abertura após 12 horas apresentou volume do dreno significativamente menor do que o grupo com tempo de abertura após 6 horas (p = 0,0003). Contudo, não foi verificada diferença significativa no delta absoluto das variáveis laboratoriais entre os dois grupos. CONCLUSÃO : A abertura do dreno em seis e 12 horas não demonstrou diferença significativa dos valores laboratoriais. Porém, o volume de sangue drenado foi maior com abertura do dreno após seis horas. .


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Soil Flood-Bypass Channel , Prostheses and Implants
7.
Rev. bras. ortop ; 46(3): 325-328, 2011. ilus
Article in Portuguese | LILACS | ID: lil-597808

ABSTRACT

Os autores relatam a rara ocorrência de dois casos de fratura do componente tibial em artroplastia total do joelho, fazem uma revisão da literatura e discutem os principais fatores que podem causar as falhas dos implantes.


The authors report the rare occurrence of two cases of fracture of the tibial component in total knee arthroplasty. They review the literature and discuss the main factors that can cause failure of the implants.


Subject(s)
Humans , Male , Aged , Arthroplasty, Replacement, Knee , Postoperative Complications
8.
Rev. bras. ortop ; 44(6): 475-478, 2009. ilus
Article in Portuguese | LILACS | ID: lil-538061

ABSTRACT

O desgaste do polietileno tibial utilizado nas artroplastias de joelho origina partículas que, quando fagocitadas, dão início à cascata de eventos biológicos que levam à osteólise e consequente afrouxamento dos componentes da prótese. Assim sendo, alternativas para o polietileno têm sido pesquisadas com o objetivo de minimizar o desgaste e, com isso, aumentar a durabilidade das artroplastias. Uma dessas opções é a utilização de polietilenos tibiais móveis, que apresentam maior conformidade do que os polietilenos fixos, ao mesmo tempo em que permitem autoalinhamento rotacional entre os componentes, melhorando, dessa forma, a cinética e a cinemática da prótese. São apresentados aqui, de forma resumida, porém abrangente, o conceito, os fundamentos biomecânicos, as indicações, os resultados esperados e complicações dos polietilenos tibiais móveis nas artroplastias totais do joelho.


Debris of polyethylene tibial bearings have been recognized as a major cause for the onset of the cascade of biological events leading to osteolysis and loosening of prosthetic components after total knee arthroplasty. Since then, research has been focused on alternative bearing surfaces in order to minimize the amount and rate of polyethylene wear off and, in doing so, increasing the survivorship rate for knee arthroplasties. One such option is to have a mobile tibial bearing allowing more conformity and rotational self-alignment of the components, improving kinetics and kinematics of the prosthesis. The authors present a resumed but throughout and comprehensive review of the rationale, biomechanics fundamentals, indications, pitfalls, outcomes and complications for the use of mobile tibial bearings in total knee replacement.


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Biomechanical Phenomena , Knee/surgery , Polyethylene
9.
Rev. bras. ortop ; 32(5): 374-6, maio. 1997. ilus, tab
Article in Portuguese | LILACS | ID: lil-209749

ABSTRACT

Os autores apresentam 22 casos de artroplastia unicompartimental do joelho operados pelo grupo de joelho do INTO-HTO-RJ, no período compreendido entre fevereiro/90 e agosto/96, com seguimento médio de 56,70 meses; dois casos foram excluídos: um por näo acompanhar o protocolo de revisöes e o outro por ter-se extraviado o prontuário. Do total de pacientes operados, cinco casos evoluíram com resultado insatisfatório, necessitando conversäo para artroplastia total do joelho, sendo dois casos de osteonecrose e três de osteoartrose. Os resultados nos demais pacientes da série foram considerados como excelentes do ponto de vista clínico e radiológico. Concluem os autores que os resultados säo animadores, devendo ser considerada como boa opçÒo terapêutica no tratamento da patologia degenerativa monocompartimental do joelho.


Subject(s)
Humans , Male , Female , Middle Aged , Knee Prosthesis/methods , Aged, 80 and over , Follow-Up Studies , Postoperative Complications , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL